AnsweredAAbutPierQ&A #1872932004-08-02 20:04 · Views 46

Question on seismic analysis modeling

AAbutPier에서 생성된 sap input data는 교각기초단이 spring으로 되어 있는데, 보다 더 안전측으로 하기 위해 pix단으로 하고 했을시 AAbutPier의 내진해석 모델링 부분에서 화면출력이 이상하게 나옵니다... 궁금한 사항을 조속히 처리해 주시면 고맙겠습니다.

Answer

안녕하세요. 한길아이티입니다. 보내주신 데이타는 [일반입력]-[기초자료]-[설계환경]-"내진해석시 기초부모델링 방법" 의 선택이 "기초형식 및 지반상수 고려"로 설정이 되어 있습니다. 선택사항을 "기초중심을 고정단으로 고려"로 변경하신 후 다시 내진해석을 하시면 이상이 없습니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1812026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2222026-09-29
AnsweredAAbutPier#268520Pier seismic check2572026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K2022026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3702026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check2032026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2242026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3132026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2742026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1942026-09-18
AnsweredAAbutPier#268451Changing bearing location922026-09-18
AnsweredAAbutPier#268445Main rebar placement3062026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4112026-09-17
AnsweredAAbutPier#268433Pier alignment center1892026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2372026-09-17
AnsweredAAbutPier#268422Question about pier2752026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2632026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3982026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2262026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1802026-09-16
Sign in to ask