Skip to content
AnsweredAAbutPierQ&A #1856292004-04-30 19:02 · Views 8

[***] Re-uploading alignment data

다시 수정한 선형데이타입니다..죄송

Answer

안녕하세요. 한길아이티입니다. 선형을 변경하여 적용한 후 확인하시면 이상이 없습니다. 입력데이타 중 몇가지는 수정을 하셔야 할 것 같습니다. 1) 내진해석 단면에서의 PSC빔의 제원 및 중량 2) 내진해석 가로보 단면에서의 가로보 중량 3) 교각3,교각4의 교량받침의 Kv값 4) 교각위치의 지반정보 위치 및 포아슨비,탄성계수등. (현재의 입력은 기초위치의 지반정보가 없으며 포아슨비등이 누락되었습니다.) 수정된 파일을 첨부하니 참조하시고 수정후 확인하여 주시기 바랍니다. (수정값은 임의로 적용하였습니다.) 감사합니다.

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1812026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2222026-09-29
AnsweredAAbutPier#268520Pier seismic check2572026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K2022026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3762026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check2032026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2242026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3132026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2742026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1942026-09-18
AnsweredAAbutPier#268451Changing bearing location922026-09-18
AnsweredAAbutPier#268445Main rebar placement3102026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4112026-09-17
AnsweredAAbutPier#268433Pier alignment center1892026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2402026-09-17
AnsweredAAbutPier#268422Question about pier2772026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2682026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3982026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2262026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1802026-09-16
Sign in to ask