Values jump abnormally at pier expansion joint when placing PSC beams
안녕하십니까... PSC Beam L=35.0m Beam 배치시 교각 신축이음부에서 Beam 배치가 이상한데여 확인 하여 주시기 바랍니다 Beam 배치 작업은 1. 시점과 옵셋 각도 유지 2. 시점부 Shoe 자동계산 3. 현재 Shoe 위치 기준 지간장 자동계산 순으로 작업을 했고요 다른교량은 문제 없이 작업이 되었습니다
Answer
안녕하세요. 한길아이티입니다. [PSC 빔 교량, 5@35 = 205m, 110도 사교, 크로소이드 곡선 교량]입니다. 말씀하신 방법의 "거더 자동 배치 최적화 반복수행" 이 버튼 기능입니다. 이 기능을 수행한 후 점검 결과 이상이 없습니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #268560 | Question about the calculation report | 182 | 2026-09-29 |
| Answered | AAbutPier | #268548 | Tendon force when placing tendons in the pier cap | 222 | 2026-09-29 |
| Answered | AAbutPier | #268520 | Pier seismic check | 257 | 2026-09-23 |
| Answered | AAbutPier | #268509 | Transverse reinforcement factor, K | 202 | 2026-09-22 |
| Answered | AAbutPier | #268492 | Girder positions in slab dimensions | 387 | 2026-09-21 |
| Answered | AAbutPier | #268483 | Transverse pile member forces are "0" in pier pile foundation check | 206 | 2026-09-21 |
| Answered | AAbutPier | #268482 | Top and bottom rebar detailing error in pier foundation STM | 227 | 2026-09-21 |
| Answered | AAbutPier | #268476 | Question about slab dimensions | 314 | 2026-09-19 |
| Answered | AAbutPier | #268470 | Settlement and bearing capacity | 275 | 2026-09-18 |
| Answered | AAbutPier | #268462 | Superstructure wind load in the calculation report | 194 | 2026-09-18 |
| Answered | AAbutPier | #268451 | Changing bearing location | 94 | 2026-09-18 |
| Answered | AAbutPier | #268445 | Main rebar placement | 330 | 2026-09-17 |
| Answered | AAbutPier | #268438 | Modeling error in seismic analysis | 413 | 2026-09-17 |
| Answered | AAbutPier | #268433 | Pier alignment center | 190 | 2026-09-17 |
| Answered | AAbutPier | #268431 | Please check the design ground surface displacement | 244 | 2026-09-17 |
| Answered | AAbutPier | #268422 | Question about pier | 278 | 2026-09-17 |
| Answered | AAbutPier | #268416 | Wprov calculation in the structural calculation report | 269 | 2026-09-17 |
| Answered | AAbutPier | #268402 | Increasing the number of column main rebars | 402 | 2026-09-16 |
| Answered | AAbutPier | #268392 | Question about cast-in-place piles | 229 | 2026-09-16 |
| Answered | AAbutPier | #268387 | Error when entering reinforcing rebar | 180 | 2026-09-16 |