Adjusting abutment width on import
[개인정보]에서 import하면 교대 폭을 임의로 조정해 줄수없나요?? 교대 전면 제원을 보면 전부 빨간색으로 되있어 교대폭을 조정해 주고 싶어도 안되는데,, 방법이 없을까요?
Answer
안녕하세요. 한길아이티입니다. 프로그램 최하단부를 보시면 초록색으로 [선형참조계산 : 자동]이라는 표시가 있습니다. 그것을 클릭하시어 회색으로 바꾸신후 입력 대화상자의 [적용] 버튼을 누르시면 값을 바꿀 수가 있습니다. 그러나 특별한 경우가 아니라면 설계교대입력에서 교대폭을 바꾸어주셔야 올바른 EL 등의 값을 얻어실 수 있습니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #268560 | Question about the calculation report | 182 | 2026-09-29 |
| Answered | AAbutPier | #268548 | Tendon force when placing tendons in the pier cap | 222 | 2026-09-29 |
| Answered | AAbutPier | #268520 | Pier seismic check | 257 | 2026-09-23 |
| Answered | AAbutPier | #268509 | Transverse reinforcement factor, K | 202 | 2026-09-22 |
| Answered | AAbutPier | #268492 | Girder positions in slab dimensions | 388 | 2026-09-21 |
| Answered | AAbutPier | #268483 | Transverse pile member forces are "0" in pier pile foundation check | 206 | 2026-09-21 |
| Answered | AAbutPier | #268482 | Top and bottom rebar detailing error in pier foundation STM | 227 | 2026-09-21 |
| Answered | AAbutPier | #268476 | Question about slab dimensions | 314 | 2026-09-19 |
| Answered | AAbutPier | #268470 | Settlement and bearing capacity | 275 | 2026-09-18 |
| Answered | AAbutPier | #268462 | Superstructure wind load in the calculation report | 194 | 2026-09-18 |
| Answered | AAbutPier | #268451 | Changing bearing location | 94 | 2026-09-18 |
| Answered | AAbutPier | #268445 | Main rebar placement | 330 | 2026-09-17 |
| Answered | AAbutPier | #268438 | Modeling error in seismic analysis | 415 | 2026-09-17 |
| Answered | AAbutPier | #268433 | Pier alignment center | 190 | 2026-09-17 |
| Answered | AAbutPier | #268431 | Please check the design ground surface displacement | 244 | 2026-09-17 |
| Answered | AAbutPier | #268422 | Question about pier | 278 | 2026-09-17 |
| Answered | AAbutPier | #268416 | Wprov calculation in the structural calculation report | 269 | 2026-09-17 |
| Answered | AAbutPier | #268402 | Increasing the number of column main rebars | 402 | 2026-09-16 |
| Answered | AAbutPier | #268392 | Question about cast-in-place piles | 229 | 2026-09-16 |
| Answered | AAbutPier | #268387 | Error when entering reinforcing rebar | 181 | 2026-09-16 |