Program crashes when clicking design check
교각 갯수가 한방향당 6개씩해서 총 12개 입니다. 이 중 6번교각 단면도 제원에서 설계검토(안정검토)를 누르면 다운이 됩니다. 12번 부터 거꾸로 검토를 해보니... 7번에서도 다운이 되었습니다. 답변 부탁드립니다.
Answer
안녕하세요. 전단 및 배력철근 입력까지 진행된 후 실행하시면 이상없이 실행됩니다. 이 사항은 수정하도록하겠습니다. 한길아이티입니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #268560 | Question about the calculation report | 183 | 2026-09-29 |
| Answered | AAbutPier | #268548 | Tendon force when placing tendons in the pier cap | 223 | 2026-09-29 |
| Answered | AAbutPier | #268520 | Pier seismic check | 259 | 2026-09-23 |
| Answered | AAbutPier | #268509 | Transverse reinforcement factor, K | 204 | 2026-09-22 |
| Answered | AAbutPier | #268492 | Girder positions in slab dimensions | 391 | 2026-09-21 |
| Answered | AAbutPier | #268483 | Transverse pile member forces are "0" in pier pile foundation check | 208 | 2026-09-21 |
| Answered | AAbutPier | #268482 | Top and bottom rebar detailing error in pier foundation STM | 229 | 2026-09-21 |
| Answered | AAbutPier | #268476 | Question about slab dimensions | 317 | 2026-09-19 |
| Answered | AAbutPier | #268470 | Settlement and bearing capacity | 276 | 2026-09-18 |
| Answered | AAbutPier | #268462 | Superstructure wind load in the calculation report | 195 | 2026-09-18 |
| Answered | AAbutPier | #268451 | Changing bearing location | 94 | 2026-09-18 |
| Answered | AAbutPier | #268445 | Main rebar placement | 332 | 2026-09-17 |
| Answered | AAbutPier | #268438 | Modeling error in seismic analysis | 418 | 2026-09-17 |
| Answered | AAbutPier | #268433 | Pier alignment center | 190 | 2026-09-17 |
| Answered | AAbutPier | #268431 | Please check the design ground surface displacement | 244 | 2026-09-17 |
| Answered | AAbutPier | #268422 | Question about pier | 279 | 2026-09-17 |
| Answered | AAbutPier | #268416 | Wprov calculation in the structural calculation report | 269 | 2026-09-17 |
| Answered | AAbutPier | #268402 | Increasing the number of column main rebars | 404 | 2026-09-16 |
| Answered | AAbutPier | #268392 | Question about cast-in-place piles | 231 | 2026-09-16 |
| Answered | AAbutPier | #268387 | Error when entering reinforcing rebar | 182 | 2026-09-16 |