Skip to content
AnsweredAAbutPierQ&A #1829582003-10-14 18:50 · Views 91

About the rebar reinforcement drawing...

좀전에 전화통화한 사람입니다. 첨부파일 올립니다. 팩스보내드린것과 함께 확인부탁드립니다.

Answer

안녕하세요. 한길아이티입니다. 1. 교각 두부보 주철근(C1) 개수 산정시 오류가 있었습니다. 수정하였습니다. 2. 교각 두부보 주철근(C2) 개수 오류 없습니다. 3. 기초 주철근 (B5) 마크 표현시 오류 수정하였습니다. 4. 기초 평면도 전단철근(B7) 개수는 오류가 없습니다. 5. 기둥부 배근의 크로스 타이(P7)의 개수는 오류가 없습니다. 다만 입력시에 기둥 띠철근이 배근 상태가 없는곳에도 크로스 타이 배근이 되어 있습니다. 수정하여 주십시오. 감사합니다.

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1832026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2232026-09-29
AnsweredAAbutPier#268520Pier seismic check2592026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K2052026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3912026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check2102026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2292026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3182026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2772026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1952026-09-18
AnsweredAAbutPier#268451Changing bearing location942026-09-18
AnsweredAAbutPier#268445Main rebar placement3332026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4192026-09-17
AnsweredAAbutPier#268433Pier alignment center1912026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2452026-09-17
AnsweredAAbutPier#268422Question about pier2792026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2692026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars4062026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2322026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1822026-09-16
Sign in to ask