Question in Korean (English title coming soon)
다주식 교각 검토시 기초의 단면력 산정에서 자중과 말뚝 반력이 0으로 들어갑니다. 확인부탁드립니다.
Answer
안녕하세요. 한길아이티입니다. 말뚝의 반력이 안들어오는 것은 아니며, 교각입력-설계환경-설계선택사항-기초의 전단검토시 위험단면 위치에서 기초의 검토위치가 기둥전면에서 d만큼 떨어진 곳이므로 (기초의 d=1100이므로 1100만큼 떨어진 곳에는 기초가 존재하지 않습니다.) Vb가 O으로 나오는 것입니다. 위험단면의 위치를 벽체전면으로 선택시 Vb계산 가능합니다. (그림 생략) 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #268560 | Question about the calculation report | 177 | 2026-09-29 |
| Answered | AAbutPier | #268548 | Tendon force when placing tendons in the pier cap | 213 | 2026-09-29 |
| Answered | AAbutPier | #268520 | Pier seismic check | 242 | 2026-09-23 |
| Answered | AAbutPier | #268509 | Transverse reinforcement factor, K | 190 | 2026-09-22 |
| Answered | AAbutPier | #268492 | Girder positions in slab dimensions | 330 | 2026-09-21 |
| Answered | AAbutPier | #268483 | Transverse pile member forces are "0" in pier pile foundation check | 198 | 2026-09-21 |
| Answered | AAbutPier | #268482 | Top and bottom rebar detailing error in pier foundation STM | 215 | 2026-09-21 |
| Answered | AAbutPier | #268476 | Question about slab dimensions | 300 | 2026-09-19 |
| Answered | AAbutPier | #268470 | Settlement and bearing capacity | 263 | 2026-09-18 |
| Answered | AAbutPier | #268462 | Superstructure wind load in the calculation report | 189 | 2026-09-18 |
| Answered | AAbutPier | #268451 | Changing bearing location | 86 | 2026-09-18 |
| Answered | AAbutPier | #268445 | Main rebar placement | 258 | 2026-09-17 |
| Answered | AAbutPier | #268438 | Modeling error in seismic analysis | 397 | 2026-09-17 |
| Answered | AAbutPier | #268433 | Pier alignment center | 186 | 2026-09-17 |
| Answered | AAbutPier | #268431 | Please check the design ground surface displacement | 217 | 2026-09-17 |
| Answered | AAbutPier | #268422 | Question about pier | 244 | 2026-09-17 |
| Answered | AAbutPier | #268416 | Wprov calculation in the structural calculation report | 232 | 2026-09-17 |
| Answered | AAbutPier | #268402 | Increasing the number of column main rebars | 382 | 2026-09-16 |
| Answered | AAbutPier | #268392 | Question about cast-in-place piles | 217 | 2026-09-16 |
| Answered | AAbutPier | #268387 | Error when entering reinforcing rebar | 170 | 2026-09-16 |