안양방향(빔교) P17의 전,후 빔개수가 5개,6개로 다릅니다.. 코핑의 단차를 전,후 다르게 주어야 되는데 먹히지가 않네요.. 검토해주시기 바랍니다..
Answer
안녕하세요. 한길아이티입니다. 질의하신 내용은 종방향 변단면교각으로 판단되어지며 아래와 같이 실행하시면 됩니다. 1. 교각입력-설계환경-두부보 종방향 변단면 체크 2. 교각입력-단면도제원-두부보 종방향 변단면 탭에서 권고안 클릭하거나, 선형참조수동으로 바꾼상태에서 제원을 입력하실수도 있습니다. 3. 교각입력-두부보 제원입력에서 권고안 클릭. (그림 생략) 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #268560 | Question about the calculation report | 178 | 2026-09-29 |
| Answered | AAbutPier | #268548 | Tendon force when placing tendons in the pier cap | 213 | 2026-09-29 |
| Answered | AAbutPier | #268520 | Pier seismic check | 242 | 2026-09-23 |
| Answered | AAbutPier | #268509 | Transverse reinforcement factor, K | 190 | 2026-09-22 |
| Answered | AAbutPier | #268492 | Girder positions in slab dimensions | 330 | 2026-09-21 |
| Answered | AAbutPier | #268483 | Transverse pile member forces are "0" in pier pile foundation check | 198 | 2026-09-21 |
| Answered | AAbutPier | #268482 | Top and bottom rebar detailing error in pier foundation STM | 215 | 2026-09-21 |
| Answered | AAbutPier | #268476 | Question about slab dimensions | 300 | 2026-09-19 |
| Answered | AAbutPier | #268470 | Settlement and bearing capacity | 263 | 2026-09-18 |
| Answered | AAbutPier | #268462 | Superstructure wind load in the calculation report | 189 | 2026-09-18 |
| Answered | AAbutPier | #268451 | Changing bearing location | 87 | 2026-09-18 |
| Answered | AAbutPier | #268445 | Main rebar placement | 260 | 2026-09-17 |
| Answered | AAbutPier | #268438 | Modeling error in seismic analysis | 397 | 2026-09-17 |
| Answered | AAbutPier | #268433 | Pier alignment center | 186 | 2026-09-17 |
| Answered | AAbutPier | #268431 | Please check the design ground surface displacement | 217 | 2026-09-17 |
| Answered | AAbutPier | #268422 | Question about pier | 244 | 2026-09-17 |
| Answered | AAbutPier | #268416 | Wprov calculation in the structural calculation report | 232 | 2026-09-17 |
| Answered | AAbutPier | #268402 | Increasing the number of column main rebars | 382 | 2026-09-16 |
| Answered | AAbutPier | #268392 | Question about cast-in-place piles | 218 | 2026-09-16 |
| Answered | AAbutPier | #268387 | Error when entering reinforcing rebar | 170 | 2026-09-16 |