Question in Korean (English title coming soon)
교대배력철근에서 설계검토는 모두 OK이나... 왼쪽 입력창에는 X 표시가 되어있습니다.. 그리고 설계검토시 전면저판 배력철근의 Vn값이 #으로 나옵니다.. 검토부탁드립니다..
Answer
안녕하세요. 한길아이티입니다. 앞굽에 전단철근을 배근하지 않으셨습니다. 배근하지 않았기 때문에 철근량을 산정할수 없어서 오류를 나타내었던것이었으며, 또한 그때문에 메뉴트리에서 x 표시가 나왔던것입니다. 하면의 기초 전단철근의 간격을 ctc 300으로 바꾼다거나 사용자배치로 앞굽에 전단철근 배근시 메뉴트리의 x표식 및 설계검토의 누락된 값은 사라집니다. (그림 생략) 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #268560 | Question about the calculation report | 178 | 2026-09-29 |
| Answered | AAbutPier | #268548 | Tendon force when placing tendons in the pier cap | 213 | 2026-09-29 |
| Answered | AAbutPier | #268520 | Pier seismic check | 242 | 2026-09-23 |
| Answered | AAbutPier | #268509 | Transverse reinforcement factor, K | 190 | 2026-09-22 |
| Answered | AAbutPier | #268492 | Girder positions in slab dimensions | 330 | 2026-09-21 |
| Answered | AAbutPier | #268483 | Transverse pile member forces are "0" in pier pile foundation check | 198 | 2026-09-21 |
| Answered | AAbutPier | #268482 | Top and bottom rebar detailing error in pier foundation STM | 215 | 2026-09-21 |
| Answered | AAbutPier | #268476 | Question about slab dimensions | 301 | 2026-09-19 |
| Answered | AAbutPier | #268470 | Settlement and bearing capacity | 264 | 2026-09-18 |
| Answered | AAbutPier | #268462 | Superstructure wind load in the calculation report | 189 | 2026-09-18 |
| Answered | AAbutPier | #268451 | Changing bearing location | 87 | 2026-09-18 |
| Answered | AAbutPier | #268445 | Main rebar placement | 261 | 2026-09-17 |
| Answered | AAbutPier | #268438 | Modeling error in seismic analysis | 398 | 2026-09-17 |
| Answered | AAbutPier | #268433 | Pier alignment center | 186 | 2026-09-17 |
| Answered | AAbutPier | #268431 | Please check the design ground surface displacement | 218 | 2026-09-17 |
| Answered | AAbutPier | #268422 | Question about pier | 245 | 2026-09-17 |
| Answered | AAbutPier | #268416 | Wprov calculation in the structural calculation report | 232 | 2026-09-17 |
| Answered | AAbutPier | #268402 | Increasing the number of column main rebars | 382 | 2026-09-16 |
| Answered | AAbutPier | #268392 | Question about cast-in-place piles | 218 | 2026-09-16 |
| Answered | AAbutPier | #268387 | Error when entering reinforcing rebar | 170 | 2026-09-16 |