Question in Korean (English title coming soon)
기초와 기둥의 콘크리트 강도가 다른데 모두 40MPa로 집계돼고 굵은 골재치수를 변경해도 P1만 변경됩니다.
Answer
안녕하세요. 한길아이티입니다. 질의하신 부분은 입력은 설계환경의 fck를 40MPa로 동일하게 입력하셨으며 굵은골재치수 또한 동일하게 25mm로 입력하셨기에 그렇게 나오고 있는것입니다. 원하시는 곳의 콘크리트 강도와 굵은골재 치수를 입력하시면 됩니다. (그림 생략) 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #268560 | Question about the calculation report | 178 | 2026-09-29 |
| Answered | AAbutPier | #268548 | Tendon force when placing tendons in the pier cap | 213 | 2026-09-29 |
| Answered | AAbutPier | #268520 | Pier seismic check | 242 | 2026-09-23 |
| Answered | AAbutPier | #268509 | Transverse reinforcement factor, K | 190 | 2026-09-22 |
| Answered | AAbutPier | #268492 | Girder positions in slab dimensions | 330 | 2026-09-21 |
| Answered | AAbutPier | #268483 | Transverse pile member forces are "0" in pier pile foundation check | 198 | 2026-09-21 |
| Answered | AAbutPier | #268482 | Top and bottom rebar detailing error in pier foundation STM | 215 | 2026-09-21 |
| Answered | AAbutPier | #268476 | Question about slab dimensions | 301 | 2026-09-19 |
| Answered | AAbutPier | #268470 | Settlement and bearing capacity | 264 | 2026-09-18 |
| Answered | AAbutPier | #268462 | Superstructure wind load in the calculation report | 189 | 2026-09-18 |
| Answered | AAbutPier | #268451 | Changing bearing location | 87 | 2026-09-18 |
| Answered | AAbutPier | #268445 | Main rebar placement | 261 | 2026-09-17 |
| Answered | AAbutPier | #268438 | Modeling error in seismic analysis | 398 | 2026-09-17 |
| Answered | AAbutPier | #268433 | Pier alignment center | 186 | 2026-09-17 |
| Answered | AAbutPier | #268431 | Please check the design ground surface displacement | 218 | 2026-09-17 |
| Answered | AAbutPier | #268422 | Question about pier | 245 | 2026-09-17 |
| Answered | AAbutPier | #268416 | Wprov calculation in the structural calculation report | 232 | 2026-09-17 |
| Answered | AAbutPier | #268402 | Increasing the number of column main rebars | 382 | 2026-09-16 |
| Answered | AAbutPier | #268392 | Question about cast-in-place piles | 218 | 2026-09-16 |
| Answered | AAbutPier | #268387 | Error when entering reinforcing rebar | 170 | 2026-09-16 |