AnsweredAAbutPierQ&A #2084852007-11-20 16:07 · Views 26

Question in Korean (English title coming soon)

교좌면 제원에서 설계검토를 하면 수직력 수평력이 나옵니다. 그 수평력부분에서 탄성지지력은 설계환경부분 지진하중에서 수평력하고 값이 상이한데 어디서 나오는 값인지 궁금합니다. 아래 첨부화일에 프린트스크린정리한 엑셀화일과 에이피어 화일을 함께올립니다.

Answer

안녕하세요. 한길아이티입니다. 교좌의 수평력 검토에 나오는 수평력값은 지진하중(받침)/응답수정계수로 적용된 값입니다. 자세한 사항은 첨부하는 파일 참조하시면 됩니다. 감사합니다.

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1782026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2132026-09-29
AnsweredAAbutPier#268520Pier seismic check2422026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K1902026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3302026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check1982026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2152026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3012026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2642026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1892026-09-18
AnsweredAAbutPier#268451Changing bearing location872026-09-18
AnsweredAAbutPier#268445Main rebar placement2612026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis3982026-09-17
AnsweredAAbutPier#268433Pier alignment center1862026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2192026-09-17
AnsweredAAbutPier#268422Question about pier2462026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2322026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3822026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2182026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1702026-09-16
Sign in to ask