안녕하세요. 한길아이티입니다. 1.교대 주철근에 입력시 비활성화 되어있는 피복은 설계환경-피복란에 있는 수치를 가지고 1단피복을 사용하기 때문에 입력을 주철근입력시 안되도록 되어 있는 부분입니다. 2.전단및 배력철근입력시 B구간의 주철근=C구간의 배력철근, C구간의 주철근=B구간의 배력철근과 동일하므로 B,C구간의 배력철근은 주철근입력으로 자동설정되는것입니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #268560 | Question about the calculation report | 179 | 2026-09-29 |
| Answered | AAbutPier | #268548 | Tendon force when placing tendons in the pier cap | 216 | 2026-09-29 |
| Answered | AAbutPier | #268520 | Pier seismic check | 245 | 2026-09-23 |
| Answered | AAbutPier | #268509 | Transverse reinforcement factor, K | 191 | 2026-09-22 |
| Answered | AAbutPier | #268492 | Girder positions in slab dimensions | 332 | 2026-09-21 |
| Answered | AAbutPier | #268483 | Transverse pile member forces are "0" in pier pile foundation check | 198 | 2026-09-21 |
| Answered | AAbutPier | #268482 | Top and bottom rebar detailing error in pier foundation STM | 215 | 2026-09-21 |
| Answered | AAbutPier | #268476 | Question about slab dimensions | 304 | 2026-09-19 |
| Answered | AAbutPier | #268470 | Settlement and bearing capacity | 268 | 2026-09-18 |
| Answered | AAbutPier | #268462 | Superstructure wind load in the calculation report | 190 | 2026-09-18 |
| Answered | AAbutPier | #268451 | Changing bearing location | 87 | 2026-09-18 |
| Answered | AAbutPier | #268445 | Main rebar placement | 263 | 2026-09-17 |
| Answered | AAbutPier | #268438 | Modeling error in seismic analysis | 401 | 2026-09-17 |
| Answered | AAbutPier | #268433 | Pier alignment center | 186 | 2026-09-17 |
| Answered | AAbutPier | #268431 | Please check the design ground surface displacement | 223 | 2026-09-17 |
| Answered | AAbutPier | #268422 | Question about pier | 247 | 2026-09-17 |
| Answered | AAbutPier | #268416 | Wprov calculation in the structural calculation report | 234 | 2026-09-17 |
| Answered | AAbutPier | #268402 | Increasing the number of column main rebars | 387 | 2026-09-16 |
| Answered | AAbutPier | #268392 | Question about cast-in-place piles | 220 | 2026-09-16 |
| Answered | AAbutPier | #268387 | Error when entering reinforcing rebar | 172 | 2026-09-16 |