Skip to content
AnsweredAAbutPierQ&A #2061602007-09-07 19:08 · Views 22

Cannot adjust cross-section configuration

상부는 PSC빔교 입니다. 빔간격조정으로 인해 빔이 8본 에서 7본으로 수정하려고 하는데 "시점 및 횡단구성 입력" 8본일때 간격 2.5에서 7본일때 간격 2.85로 변경하면 도면상에는 반영이 안됩니다 확인부탁드립니다

Answer

안녕하세요. 한길아이티입니다. 횡단구성에서 2.85로 입력을 하였다 하더라도 지점각도입력-교량받침좌표편집에서 수정한 교량받침좌표를 on하였기 때문에 그전에 입력된 고정좌표를 가지고 있기때문에 2.5로 표기되는것입니다. 좌표를 수정해서 입력하시거나 고정좌표를 사용하시지 않아야지 원하시는 결과물을 얻을수 있읍니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1802026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2182026-09-29
AnsweredAAbutPier#268520Pier seismic check2482026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K1922026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check1982026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2162026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3062026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2692026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1912026-09-18
AnsweredAAbutPier#268451Changing bearing location872026-09-18
AnsweredAAbutPier#268445Main rebar placement2642026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4042026-09-17
AnsweredAAbutPier#268433Pier alignment center1862026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2232026-09-17
AnsweredAAbutPier#268422Question about pier2482026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2352026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3912026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2222026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1752026-09-16
Sign in to ask