AnsweredAAbutPierQ&A #2054042007-07-23 22:20 · Views 36

Seismic load input

기초자료입력시 내진설계방법을 단일모드스펙트럼으로 설정한 경우 교대해석시 지진하중값들이 자동인식해야하는것같은데.. 하중값이 나오질않습니다 확인해주세요

Answer

안녕하세요. 한길아이티입니다. [일반입력] - [내진해석 단면입력]에서 입력된 단면제원을 보시면 단면의 중량이 누락되어 있습니다. 거더,포장,방호벽등의 중량을 입력하신 후에 확인하시면 됩니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1802026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2182026-09-29
AnsweredAAbutPier#268520Pier seismic check2482026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K1922026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check1982026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2162026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3062026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2692026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1912026-09-18
AnsweredAAbutPier#268451Changing bearing location872026-09-18
AnsweredAAbutPier#268445Main rebar placement2642026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4042026-09-17
AnsweredAAbutPier#268433Pier alignment center1862026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2242026-09-17
AnsweredAAbutPier#268422Question about pier2492026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2362026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3912026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2222026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1752026-09-16
Sign in to ask