Skip to content
AnsweredAAbutPierQ&A #2053992007-07-23 11:20 · Views 50

Program feature request

날개벽 사각으로 인한 토압추가요. 날개벽이 교대와 평행하지 않고 사각을 가지고 있어서 교대 계산시 날개벽쪽의 토압이 함께 교대 벽체에 작용 해야 하는것 같은데 본프로그램에서는 적용이 않되는 내요. 프로그램에서 추가해주셔야 할것 같습니다. 설계자문 사항이라 꼭 반영을 해야 합니다. 빠른 연락 부탁합니다. 도면과 DATA, 계산서를 첨부합니다. [개인정보] [개인정보]

Answer

안녕하세요. 한길아이티입니다. 현재는 프로그램에서 지원하지 않는사항이며 그러한 사항들을 모두 고려할경우 3D해석까지 해야하는것이 바른 방법입니다. [개인정보]에서는 날개벽판해석까지는 지원할 예정입니다. 감사합니다.

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1802026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2182026-09-29
AnsweredAAbutPier#268520Pier seismic check2482026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K1922026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check1982026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2162026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3062026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2692026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1912026-09-18
AnsweredAAbutPier#268451Changing bearing location872026-09-18
AnsweredAAbutPier#268445Main rebar placement2642026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4042026-09-17
AnsweredAAbutPier#268433Pier alignment center1862026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2242026-09-17
AnsweredAAbutPier#268422Question about pier2492026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2362026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3912026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2222026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1752026-09-16
Sign in to ask