AnsweredAAbutPierQ&A #2027942007-03-21 00:06 · Views 6

Please check SPRING block error in seismic analysis

안녕하세요 일교차가 심한 날씨입니다 항상 건강 유의하시길 바랍니다 다름이 아니오라 간략적으로 교대 및 교각 계산서 산출코저 프로그램 구동중 교각부 내진 해석시에 SPRING블럭에 대한 입력값이 잘못되었다는 에러메시지와 함께 내진해석이 수행되지 않고 있습니다 지반정보 및 기초설정을 개략적으로 완수했음해도 내진해석이 진행되지 않습니다. 무엇이 문제인지 검토해주시길 바랍니다.

Answer

안녕하세요. 한길아이티입니다. 교대 기초제원설정에서 각교각별 권고안 실행후 말뚝배치를 다시 해주시기 바랍니다. 참고로 권고안 실행후 말뚝직경,길이,두께를 입력한 화일을 올려드립니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1802026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2182026-09-29
AnsweredAAbutPier#268520Pier seismic check2482026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K1922026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check1982026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2162026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3062026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2692026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1912026-09-18
AnsweredAAbutPier#268451Changing bearing location872026-09-18
AnsweredAAbutPier#268445Main rebar placement2702026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4042026-09-17
AnsweredAAbutPier#268433Pier alignment center1862026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2272026-09-17
AnsweredAAbutPier#268422Question about pier2512026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2422026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3912026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2222026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1752026-09-16
Sign in to ask