Skip to content
AnsweredAAbutPierQ&A #2024322007-02-26 23:01 · Views 76

Confirming whether loads are applied in seismic analysis

전화드렸엇는데..수고스럽게 해드려 죄송합니다. 확인부탁드립니다. 내진해석시 하중의 거더당 반력을 입력하였습니다. 그렇다면 sap에서 적용이 되었는지 확인 할수 잇는 방법이 잇나요/.?

Answer

안녕하세요. 한길아이티입니다. 우선 말씀드려야할 것은 apier에서 현재 sap data는 cgs단위계로 구성되어있읍니다. 기초자료-설계환경-중력가속도의 사용자입력값을 사용하게 되어있읍니다. 보내주신화일에서는 9.810m/sec2입니다. 내진해석단면입력에서 1번 단면의 단위m당 중량은 22.630KN/m로 입력하셨고요 따라서 내진해석 sap input에서 "FRAME SECTION NAME=GIR01 TYPE=PRISM MAT=GCONC01 MPL=0.231 A=1.122651 J=0.016803 " MPL=22.630/9.810=2.3068이므로 단위환산을 하면 0.231이 됩니다. 참고로 가로보는 단위m당 중량을 입력안하셨기때문에 " NAME=CRO01 TYPE=PRISM MAT=CBCONC01 MPL=0.000 A=0.450000 J=0.011799 " 처럼 0이 되는 것입니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1802026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2182026-09-29
AnsweredAAbutPier#268520Pier seismic check2482026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K1922026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check1982026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2162026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3062026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2692026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1912026-09-18
AnsweredAAbutPier#268451Changing bearing location872026-09-18
AnsweredAAbutPier#268445Main rebar placement2702026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4042026-09-17
AnsweredAAbutPier#268433Pier alignment center1862026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2272026-09-17
AnsweredAAbutPier#268422Question about pier2522026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2422026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3912026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2222026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1752026-09-16
Sign in to ask