Skip to content
AnsweredAAbutPierQ&A #2018052007-01-12 23:41 · Views 33

"Internal application error" message appears

안녕하세요 새해 복많이 받으시기 바랍니다. 다름이 아니라 교각10, 교각11 모델링 해석시 sap2000자동실행을 하면 "내부응용프로그램 오류입니다"라고 뜨면서 계산이 진행이 되지가 않습니다. 나머지교각은 제대로 실행이 되는데... 파일 첨부하오니 검토 부탁드립니다..

Answer

안녕하세요. 한길아이티입니다. [개인 정보]과장님도 새해복많이 받으세요 보내주신화일 검토한 결과 교각설계환경입력에서 P10,P11의 사용하중조합,계수하중조합,계수하중조합(최대편심)이 누락되어 있읍니다.권고안실행후 하중조합을 확인후 교각모델링해석을 하시면 문제가 없읍니다. 감사합니다.

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1802026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2182026-09-29
AnsweredAAbutPier#268520Pier seismic check2482026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K1922026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check1982026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2162026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3062026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2692026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1912026-09-18
AnsweredAAbutPier#268451Changing bearing location872026-09-18
AnsweredAAbutPier#268445Main rebar placement2712026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4042026-09-17
AnsweredAAbutPier#268433Pier alignment center1862026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2292026-09-17
AnsweredAAbutPier#268422Question about pier2522026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2432026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3912026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2222026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1752026-09-16
Sign in to ask