Skip to content
AnsweredAAbutPierQ&A #2013092006-12-07 02:30 · Views 41

Structural calculation report output error

- 교대 구조계산서 <해석결과 요약표> 필요 철근량(Req. As)과 단면검토시 <철근량 산정> 에 필요 철근량이 서로 상이 합니다. 검토후 답변 바랍니다......

Answer

안녕하세요. 한길아이티입니다. <해석결과 요약표> 필요 철근량(Req. As)는 단면검토시 Req. As외에 철근비에 의한 값입니다. 예로 흉벽 계산시 Req. As=1774.875 , 철근비검토시 4/3 Req. As=2367.0 이므로 결과요약에는 2367.0으로 표현되는것입니다. 실제로 필요한 철근량은 철근비 검토시의 양이기 때문에 2367.0으로 표기한것입니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1802026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2182026-09-29
AnsweredAAbutPier#268520Pier seismic check2482026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K1922026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check1982026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2162026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3062026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2692026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1912026-09-18
AnsweredAAbutPier#268451Changing bearing location872026-09-18
AnsweredAAbutPier#268445Main rebar placement2712026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4042026-09-17
AnsweredAAbutPier#268433Pier alignment center1862026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2302026-09-17
AnsweredAAbutPier#268422Question about pier2522026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2452026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3912026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2222026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1752026-09-16
Sign in to ask