Skip to content
AnsweredAAbutPierQ&A #2010902006-11-16 10:12 · Views 47

Please check superstructure and substructure coordinates

상부에서 출력되는 shoe좌표 하고 brx민들어서 하부에서 불러드린 shoe좌표값이 상이하네요. 확인 부탁드립니다,

Answer

안녕하세요. 한길아이티입니다. 검토한 결과 좌표가 상이한 부분이 발견되었읍니다. aroad:지점각도입력-시점offset처리,종점 offset처리가 off가 되어A1,A2의 각도가 119,111로 되어있읍니다. apier:지점각도입력-교량받침지점각도 사용자 입력이 off되어서 A1(교량받침),A2(교량받침)의 각도가 118.7412 , 111.2588가 되었읍니다. 따라서 좌표가 상이하게 되는것입니다. 사용자께서는 apier:교량받침 지점각도 사용자 입력을 on하신후 A1(교량받침),A2(교량받침)의 각도를 상부(aroad)와 같이 119,111으로 설정하시면 좌표가 같게 되는것을 확인하실 수 있읍니다. araod의 옵션과 apier와 호환안되는점은 빠른시일내에 호환되도록 하겠읍니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1802026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2182026-09-29
AnsweredAAbutPier#268520Pier seismic check2482026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K1922026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check1982026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2162026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3062026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2692026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1912026-09-18
AnsweredAAbutPier#268451Changing bearing location872026-09-18
AnsweredAAbutPier#268445Main rebar placement2712026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4042026-09-17
AnsweredAAbutPier#268433Pier alignment center1862026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2302026-09-17
AnsweredAAbutPier#268422Question about pier2522026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2452026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3912026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2222026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1752026-09-16
Sign in to ask