AnsweredAAbutPierQ&A #2001662006-09-15 20:02 · Views 18

Entering bearing seat dimensions

교대, 교각 교좌면 제원 입력에서 제원참조를 통해서 유니슨 포트받침을 선택하여 적용을 하였는데 수치가 적용이 안됩니다. 또한 내진해석 모델링에서 Sap2000 자동실행을 누르면 해당 디렉토리에 화일이 없다는 메시지와 함께 Running이 안됩니다. 물런 해당 디렉에 화일은 있지만요.. 수정바랍니다.

Answer

안녕하세요. 한길아이티입니다. 1.brx를 import시 작업시에는 슈제원를 고쳐도 적용이 되지 않읍니다. 일단 작업을 하신후 저장한후에 다시여시면 슈에 대한 수정이 가능합니다. 2.화일명이 빈공간이나 특수문자등 일반적이지 않은경우에 sap에서 인식을 못합니다. 화일명에 빈공간을 삭제하시면 원할히 됩니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1802026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2182026-09-29
AnsweredAAbutPier#268520Pier seismic check2482026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K1922026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check1982026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2162026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3062026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2692026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1912026-09-18
AnsweredAAbutPier#268451Changing bearing location872026-09-18
AnsweredAAbutPier#268445Main rebar placement2762026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4042026-09-17
AnsweredAAbutPier#268433Pier alignment center1862026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2312026-09-17
AnsweredAAbutPier#268422Question about pier2552026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2452026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3912026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2222026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1752026-09-16
Sign in to ask