AnsweredAAbutPierQ&A #1991932006-07-03 21:59 · Views 32

Entering subgrade reaction modulus manually

보통 구조쪽에서 지반반력계수(kh, kv)는 도로교설계기준에서 제시한 식에 의해 구하나, 지반부에서는 지반반력계수값을 여러식들을 종합적으로 판단하여 지반보고서에 제시합니다. 따라서 구조계산서상의 β, kh, kv값이 지반보고서와 상이 할 수 있어, AAbutPier상에 β,kh,kv값을 수동으로 입력하게 하여 기초를 설계하게 해주었으면 좋겠습니다. 이는 도로공사에서 요구하는 사항이므로 조속한 시간에 해결해 주셨으면 감사하겠습니다.

Answer

안녕하세요. 한길아이티입니다. 지반반력계수의 사용자 입력은 차기버전에 반영하도록 하겠습니다. 자세한 사항은 전화로 말씀드렸습니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1802026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2182026-09-29
AnsweredAAbutPier#268520Pier seismic check2482026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K1922026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check1982026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2162026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3062026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2692026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1912026-09-18
AnsweredAAbutPier#268451Changing bearing location872026-09-18
AnsweredAAbutPier#268445Main rebar placement2792026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4042026-09-17
AnsweredAAbutPier#268433Pier alignment center1862026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2332026-09-17
AnsweredAAbutPier#268422Question about pier2602026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2462026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3912026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2222026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1752026-09-16
Sign in to ask