AnsweredAAbutPierQ&A #1988272006-05-26 00:45 · Views 32

Seismic analysis results look wrong, please check urgently

내진해석결과 수평력이 고정단과 일방향슈에선 매우 크게나오고 양방향지점에선 0값이 나옵니다. 검토 부탁드립니다.

Answer

안녕하세요. 한길아이티입니다. 교좌장치를 입력하지 않았습니다. 교좌면 제원입력에서 교량받침 제원참조를 클릭하셔서 해당 받침을 선택하시거나 Kv/Kh 값을 수동입력하시면 정상적으로 해석됩니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1802026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2182026-09-29
AnsweredAAbutPier#268520Pier seismic check2482026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K1922026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check1982026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2162026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3062026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2692026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1912026-09-18
AnsweredAAbutPier#268451Changing bearing location872026-09-18
AnsweredAAbutPier#268445Main rebar placement2842026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4042026-09-17
AnsweredAAbutPier#268433Pier alignment center1862026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2332026-09-17
AnsweredAAbutPier#268422Question about pier2602026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2472026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3912026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2222026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1752026-09-16
Sign in to ask