Skip to content
AnsweredAAbutPierQ&A #1986752006-05-08 23:11 · Views 58

Program

내진해석 가로보 설정에서 데이타 값을 넣으면 "내부응용프로그램 오류입니다"가 뜨는데 왜 그런지 확인 좀 부탁드리겠습니다. 수고하세요.

Answer

안녕하세요. 한길아이티입니다. 보내주신 교량의 경우 각각의 지간별로 1개(지점부 제외)의 가로보를 배치하시려는 것 으로 판단됩니다. (현재입력된 파일이 어떻게 지금처럼 되었는지는 판단하기 어렵습니다.) 작업하시는 순서는 1) 기준간격에 15000(mm)의 값을 입력하신 후 -> 권고안 2) 도로중심에서 중간의 작은 치수를 삭제 (혹은 1)의 과정에서 조금 더 큰 값을 입력) 3) "위치간격 자동설정"을 수행하시면 됩니다. 임의로 조정한 파일을 첨부하니 참조하시기 바랍니다. 감사합니다.

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1802026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2182026-09-29
AnsweredAAbutPier#268520Pier seismic check2482026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K1922026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check1982026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2162026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3062026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2692026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1912026-09-18
AnsweredAAbutPier#268451Changing bearing location872026-09-18
AnsweredAAbutPier#268445Main rebar placement2842026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4042026-09-17
AnsweredAAbutPier#268433Pier alignment center1862026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2332026-09-17
AnsweredAAbutPier#268422Question about pier2612026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2472026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3912026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2222026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1752026-09-16
Sign in to ask