Reinforcement detailing of the pier bearing seat

교각 교좌면 배근에서 교량받침보강철근 검토시 2단 포함 교좌하면보강철근 사방향 배치 ---- 어느 경우에 체크해야 되나요??

Answer

안녕하세요. 한길아이티입니다. 1) 교각 교좌면 배근에서 교량받침보강철근 검토시 2단 포함 => 받침보강철근의 경우 검토시에 수평력에 대한 보강으로 검토를 합니다. 이 경우에 적용되는 철근량은 수직 다리수이며 2단이상의 철근인 경우에는 검토시에 수직다리수를 포함하지 않는 경우가 있어 옵션으로 처리되었습니다. 2) 교좌하면보강철근 사방향 배치 => 표현 그대로 두부보가 SKEW를 가지는 경우에 직사각형 형태가 아닌 평행사변형 형태로 하면 보강철근이 배치되는 옵션입니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1802026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2182026-09-29
AnsweredAAbutPier#268520Pier seismic check2482026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K1922026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check1982026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2162026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3062026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2692026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1912026-09-18
AnsweredAAbutPier#268451Changing bearing location872026-09-18
AnsweredAAbutPier#268445Main rebar placement2842026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4042026-09-17
AnsweredAAbutPier#268433Pier alignment center1862026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2342026-09-17
AnsweredAAbutPier#268422Question about pier2612026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2492026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3912026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2222026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1752026-09-16
Sign in to ask