Skip to content
AnsweredAAbutPierQ&A #1973382006-01-25 00:28 · Views 9

Abutment calculation report output looks wrong

교대 부산방향 종점측 접속슬래브 계산서가 이상한데 확인 부탁드립니다 접속슬래브 4)받침부 설계 항목이 있는데 다른 출력물에는 않나오는데 왜 나왔는지...

Answer

안녕하세요. 한길아이티입니다. 1) 교대2 - 부산방향 A2의 접속슬래브 계산서를 출력하였으나 말씀하신 부분은 확인하지 못하였습니다. 해당 위치를 구체적으로 알려주시면 추가로 검토후 답변드리겠습니다. 2) 받침부 설계는 교대의 배면이 헌치로 처리되지않고 브래킷 형태로 처리되어 접속슬래브를 지지하는 경우에만 출력이 됩니다. 보내주신 파일의 경우 교대2만이 해당이 됩니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1802026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2182026-09-29
AnsweredAAbutPier#268520Pier seismic check2482026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K1922026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check1982026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2162026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3062026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2692026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1912026-09-18
AnsweredAAbutPier#268451Changing bearing location872026-09-18
AnsweredAAbutPier#268445Main rebar placement2892026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4042026-09-17
AnsweredAAbutPier#268433Pier alignment center1862026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2342026-09-17
AnsweredAAbutPier#268422Question about pier2622026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2492026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3912026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2222026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1752026-09-16
Sign in to ask