Skip to content
AnsweredAAbutPierQ&A #1965122005-12-01 19:16 · Views 51

Steel pipe pile stress and bearing support length

강관말뚝 응력검토시 상시허용응력이 comb에 따라 다릅니다. 받침지지길이가 상부 끝단에서 적용이 되어야하는데 교좌면 전체길이가 적용됩니다. (실제 받침길이=1600, 계산서=2300) 검토바람니다. [개인정보] [개인정보]

Answer

안녕하세요. 한길아이티입니다. 1) 강관말뚝 응력검토시 상시허용응력이 comb에 따라 다릅니다. => 하중조합에 따라 허용응력 증가계수가 적용되어 있습니다. 도로교 설계기준 2.2.2.2,(3)의 내용을 참조하시기 바랍니다. 2) 받침지지길이가 상부 끝단에서 적용이 되어야하는데 교좌면 전체길이가 적용됩니다. (실제 받침길이=1600, 계산서=2300) => 말씀하신 사항은 확인하였습니다. 보완하여 패치에 적용하도록 하겠습니다. 패치 일정은 현재 작업일정상 다음주중에 가능할 것같습니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1802026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2182026-09-29
AnsweredAAbutPier#268520Pier seismic check2482026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K1922026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check1982026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2162026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3062026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2692026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1912026-09-18
AnsweredAAbutPier#268451Changing bearing location882026-09-18
AnsweredAAbutPier#268445Main rebar placement2912026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4042026-09-17
AnsweredAAbutPier#268433Pier alignment center1862026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2342026-09-17
AnsweredAAbutPier#268422Question about pier2642026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2512026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3912026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2222026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1752026-09-16
Sign in to ask