Skip to content
AnsweredAAbutPierQ&A #1960692005-11-16 01:40 · Views 15

Cross beam and step input

가로보(내진해석 입력)에서 각도입력방법과 교각입력, 단면도제원의 단차적용이 안됩니다. 검토바랍니다.

Answer

안녕하세요. 한길아이티입니다. 1) [내진해석 가로보설정]에서의 각도입력은 "각도 수동입력"을 체크하신 후에 입력하시면 됩니다. 2) 선형을 사용한 경우에 단차에 대한 설정은 [일반입력]-[슬래브 제원 입력]에서 설정하시면 됩니다. 슬래브제원입력에서 "교좌면 단차설정"에서 단차의 적용 및 위치를 조정하실 수 있으며, 교각제원입력시는 설정된 값에 따라 자동으로 적용됩니다. 1)의 사항에 대하여 임으로 조정한 파일을 첨부하니 참조하시기 바랍니다. 감사합니다.

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1802026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2182026-09-29
AnsweredAAbutPier#268520Pier seismic check2482026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K1922026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check1982026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2162026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3062026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2692026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1912026-09-18
AnsweredAAbutPier#268451Changing bearing location882026-09-18
AnsweredAAbutPier#268445Main rebar placement2912026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4042026-09-17
AnsweredAAbutPier#268433Pier alignment center1862026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2342026-09-17
AnsweredAAbutPier#268422Question about pier2642026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2512026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3912026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2222026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1752026-09-16
Sign in to ask