Foundation stability check
다주식 교각의 기초 안정 검토에서 지지력에 대한 검토시...교축직각방향의 Q 값을 검토 부탁 드립니다.
Answer
안녕하세요. 한길아이티입니다. [교각입력]-[설계환경]-"설계조건"에서 "기초지반의 허용지지력 산정식"을 Meyerhof식으로 변경하신 후에 확인하시면 이상이 없습니다. 산식의 전개상 Hansen식의 경우 장변과 단변의 비가 2.5배를 넘는 경우 계산이 불가하며, Terzaghi식도 5배를 넘는 경우 계산이 되지않습니다. 이는 계산서를 출력하시어 계산과정에서 (-)의 수가 발생하는 것을 확인하시면 됩니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #268560 | Question about the calculation report | 180 | 2026-09-29 |
| Answered | AAbutPier | #268548 | Tendon force when placing tendons in the pier cap | 218 | 2026-09-29 |
| Answered | AAbutPier | #268520 | Pier seismic check | 249 | 2026-09-23 |
| Answered | AAbutPier | #268509 | Transverse reinforcement factor, K | 195 | 2026-09-22 |
| Answered | AAbutPier | #268492 | Girder positions in slab dimensions | 335 | 2026-09-21 |
| Answered | AAbutPier | #268483 | Transverse pile member forces are "0" in pier pile foundation check | 198 | 2026-09-21 |
| Answered | AAbutPier | #268482 | Top and bottom rebar detailing error in pier foundation STM | 217 | 2026-09-21 |
| Answered | AAbutPier | #268476 | Question about slab dimensions | 306 | 2026-09-19 |
| Answered | AAbutPier | #268470 | Settlement and bearing capacity | 270 | 2026-09-18 |
| Answered | AAbutPier | #268462 | Superstructure wind load in the calculation report | 191 | 2026-09-18 |
| Answered | AAbutPier | #268451 | Changing bearing location | 88 | 2026-09-18 |
| Answered | AAbutPier | #268445 | Main rebar placement | 291 | 2026-09-17 |
| Answered | AAbutPier | #268438 | Modeling error in seismic analysis | 405 | 2026-09-17 |
| Answered | AAbutPier | #268433 | Pier alignment center | 187 | 2026-09-17 |
| Answered | AAbutPier | #268431 | Please check the design ground surface displacement | 234 | 2026-09-17 |
| Answered | AAbutPier | #268422 | Question about pier | 265 | 2026-09-17 |
| Answered | AAbutPier | #268416 | Wprov calculation in the structural calculation report | 252 | 2026-09-17 |
| Answered | AAbutPier | #268402 | Increasing the number of column main rebars | 392 | 2026-09-16 |
| Answered | AAbutPier | #268392 | Question about cast-in-place piles | 224 | 2026-09-16 |
| Answered | AAbutPier | #268387 | Error when entering reinforcing rebar | 175 | 2026-09-16 |