말뚝지지력이 n.g가 나는데 원인일 찾을수 없고 값이 이상한데 확인부탁드립니다 입력에서 틀린것 같은데 확인이 않되네요 수고하세요 ^..^......
Answer
안녕하세요. 한길아이티입니다. [교각입력]-[설계환경]-"설계조건"-"수평변형지반계수(Eo)"의 입력값이 "0"으로 되어 있습니다. 기본값은 28이나 "0"으로 입력되어 말뚝의 특성치가 계산되지 못하여 잘못된 값이 산정이 됩니다. 입력값을 조정하신 후 다시 확인하여 주시기 바랍니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #268560 | Question about the calculation report | 180 | 2026-09-29 |
| Answered | AAbutPier | #268548 | Tendon force when placing tendons in the pier cap | 218 | 2026-09-29 |
| Answered | AAbutPier | #268520 | Pier seismic check | 249 | 2026-09-23 |
| Answered | AAbutPier | #268509 | Transverse reinforcement factor, K | 195 | 2026-09-22 |
| Answered | AAbutPier | #268492 | Girder positions in slab dimensions | 335 | 2026-09-21 |
| Answered | AAbutPier | #268483 | Transverse pile member forces are "0" in pier pile foundation check | 198 | 2026-09-21 |
| Answered | AAbutPier | #268482 | Top and bottom rebar detailing error in pier foundation STM | 217 | 2026-09-21 |
| Answered | AAbutPier | #268476 | Question about slab dimensions | 306 | 2026-09-19 |
| Answered | AAbutPier | #268470 | Settlement and bearing capacity | 270 | 2026-09-18 |
| Answered | AAbutPier | #268462 | Superstructure wind load in the calculation report | 191 | 2026-09-18 |
| Answered | AAbutPier | #268451 | Changing bearing location | 88 | 2026-09-18 |
| Answered | AAbutPier | #268445 | Main rebar placement | 291 | 2026-09-17 |
| Answered | AAbutPier | #268438 | Modeling error in seismic analysis | 405 | 2026-09-17 |
| Answered | AAbutPier | #268433 | Pier alignment center | 187 | 2026-09-17 |
| Answered | AAbutPier | #268431 | Please check the design ground surface displacement | 234 | 2026-09-17 |
| Answered | AAbutPier | #268422 | Question about pier | 265 | 2026-09-17 |
| Answered | AAbutPier | #268416 | Wprov calculation in the structural calculation report | 252 | 2026-09-17 |
| Answered | AAbutPier | #268402 | Increasing the number of column main rebars | 392 | 2026-09-16 |
| Answered | AAbutPier | #268392 | Question about cast-in-place piles | 224 | 2026-09-16 |
| Answered | AAbutPier | #268387 | Error when entering reinforcing rebar | 175 | 2026-09-16 |