Seismic!
내진에서 에러가 나는군요!!! 문제해결을 부탁드립니다. 그리고 슈종류에 관계없이 CONSTRAINTS로 적용을 해도 상관이 없는 것인지요?
Answer
안녕하세요. 한길아이티입니다. 1) [내진해석 가로보설정]에 보시면 가로보에 대한 단면제원이 누락되어 있습니다. 가로보 단면타입수 옆의 [+]버튼을 눌러보시면 단면제원을 입력할 수 있습니다. 2) CONSTRAINTS로 적용되는 경우는 탄성받침이 아닌 경우에 적용이 됩니다. 탄성받침 판정기준은 [교좌면 제원]에서 kh,kv값이 입력된 받침의 경우 탄성받침 으로 판정하여 NLLINK로 처리되고 있습니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #268560 | Question about the calculation report | 180 | 2026-09-29 |
| Answered | AAbutPier | #268548 | Tendon force when placing tendons in the pier cap | 219 | 2026-09-29 |
| Answered | AAbutPier | #268520 | Pier seismic check | 250 | 2026-09-23 |
| Answered | AAbutPier | #268509 | Transverse reinforcement factor, K | 197 | 2026-09-22 |
| Answered | AAbutPier | #268492 | Girder positions in slab dimensions | 335 | 2026-09-21 |
| Answered | AAbutPier | #268483 | Transverse pile member forces are "0" in pier pile foundation check | 198 | 2026-09-21 |
| Answered | AAbutPier | #268482 | Top and bottom rebar detailing error in pier foundation STM | 220 | 2026-09-21 |
| Answered | AAbutPier | #268476 | Question about slab dimensions | 306 | 2026-09-19 |
| Answered | AAbutPier | #268470 | Settlement and bearing capacity | 270 | 2026-09-18 |
| Answered | AAbutPier | #268462 | Superstructure wind load in the calculation report | 191 | 2026-09-18 |
| Answered | AAbutPier | #268451 | Changing bearing location | 88 | 2026-09-18 |
| Answered | AAbutPier | #268445 | Main rebar placement | 291 | 2026-09-17 |
| Answered | AAbutPier | #268438 | Modeling error in seismic analysis | 406 | 2026-09-17 |
| Answered | AAbutPier | #268433 | Pier alignment center | 187 | 2026-09-17 |
| Answered | AAbutPier | #268431 | Please check the design ground surface displacement | 234 | 2026-09-17 |
| Answered | AAbutPier | #268422 | Question about pier | 265 | 2026-09-17 |
| Answered | AAbutPier | #268416 | Wprov calculation in the structural calculation report | 252 | 2026-09-17 |
| Answered | AAbutPier | #268402 | Increasing the number of column main rebars | 393 | 2026-09-16 |
| Answered | AAbutPier | #268392 | Question about cast-in-place piles | 225 | 2026-09-16 |
| Answered | AAbutPier | #268387 | Error when entering reinforcing rebar | 177 | 2026-09-16 |