Horizontal force on substructure with elastomeric bearings?

3) 상부구조에 의한 하중 ① 상부반력에의한 하중 - 고정하중반력 Rd = 3226.070 ÷ (12.440 / sin105.000) = 250.490 kN/m - 활하중반력 Rl = 1608.690 ÷ (12.440 / sin105.000) = 124.910 kN/m ② 교량받침마찰력에의한 수평력 - 상부구조의 신축량 δ = α x ΔT x L = 0.000012 x 25.0 x 60.1 = 0.018026 m 교량받침의 개수 : N = 5 EA 교대의 폭원 : B = 12.879 m 탄성받침의 전단탄성계수 : kH = 1530.000 kN/m - 단위폭당 작용 수평력 Ph = kH x δ x N / B = 1530.000 x 0.018026 x 5 / 12.879 = 10.707 kN/m ③ 가동단 하부구조에 작용하는 지진시 수평력 : 탄성받침인 경우 Fm = Fm1 + Fm2 Fm1 = H1 x cosθ Fm2 = H2 x sinθ (H2 ≤ R x μs 일때) R x μs x sinθ (H2 > R x μs 일때) Fm = 47.314 x cos105.0 + 250.490 x 0.150 x sin105.0 = 48.539 kN/m H1 = 609.350 ÷ (12.440 / sin105.0) = 47.314 kN/m : 직각방향 수평력 H2 = 620.480 ÷ (12.440 / sin105.0) = 48.178 kN/m : 교축방향 수평력 [도로교설계기준 해설] (하부구조편) 5.4.3.4 (2)의 내용을 치환하여 적용 R x Kh x sinθ → H2 (교축방향 수평력) R x Kh x cosθ → H1 (직각방향 수평력) ------------------------------------------------------------------------------------------------------- "③ 가동단 하부구조에 작용하는 지진시 수평력 : 탄성받침인 경우" 에서 수평력 산정시 탄성받침은 바로 위②에서 계산했듯이 수직하중x마찰계수항이 변위x전단탄성계수로 대치되어야 하지 않겠습니까? 결국 가동단 하부구조에 작용하는 지진시 수평력은 탄성받침인 경우 지진수평력과 지진수평변위x전단탄성계수 중에서 작은값을 취해야 하지 않을까요?

Answer

안녕하세요. 말씀하신 사항이 맞습니다. 다만 지진하중을 사용자 입력으로 하여 직접 입력하셨는데, 이때 전단탄성계수x변위값을 적용하려면 변위값을 프로그램에 입력하셔야 하는데 입력하지 않아 마찰계수X수직하중으로 계산되었습니다. 지진시의 변위를 설계환경 지진하중탭에 입력하시면 이상없이 출력됩니다. 한길아이티입니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1812026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2192026-09-29
AnsweredAAbutPier#268520Pier seismic check2512026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K1992026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check1982026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2212026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3072026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2702026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1912026-09-18
AnsweredAAbutPier#268451Changing bearing location882026-09-18
AnsweredAAbutPier#268445Main rebar placement2922026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4072026-09-17
AnsweredAAbutPier#268433Pier alignment center1872026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2342026-09-17
AnsweredAAbutPier#268422Question about pier2652026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2522026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3942026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2252026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1782026-09-16
Sign in to ask