Follow-up to phone inquiry
교각형식을 기둥식으로 선택 기둥단면형상에서 중공식으로 선택하여 트랙형으로 설계하려고함. 단면도 제원에서 기둥갯수를 1개로 적용하려 하는데 안되네요!!! 검토부탁합니다.
Answer
안녕하세요. 한길아이티입니다. 교각형식에서 벽식교각을 선택하시면 됩니다. 기둥식 교각의 경우 기둥1개에 교량이 1개만 적용이 됩니다. 현재 받침 개수가 2개로 되어있어 기둥개수도 2개로 설정되고 있습니다. 형식만 벽식으로 변경하시고 기둥개수를 1개로 맞추신 후에 작업하시면 됩니다. 기타 기둥단면 모양등은 현재 입력과 동일합니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #268560 | Question about the calculation report | 181 | 2026-09-29 |
| Answered | AAbutPier | #268548 | Tendon force when placing tendons in the pier cap | 219 | 2026-09-29 |
| Answered | AAbutPier | #268520 | Pier seismic check | 251 | 2026-09-23 |
| Answered | AAbutPier | #268509 | Transverse reinforcement factor, K | 199 | 2026-09-22 |
| Answered | AAbutPier | #268492 | Girder positions in slab dimensions | 335 | 2026-09-21 |
| Answered | AAbutPier | #268483 | Transverse pile member forces are "0" in pier pile foundation check | 198 | 2026-09-21 |
| Answered | AAbutPier | #268482 | Top and bottom rebar detailing error in pier foundation STM | 221 | 2026-09-21 |
| Answered | AAbutPier | #268476 | Question about slab dimensions | 307 | 2026-09-19 |
| Answered | AAbutPier | #268470 | Settlement and bearing capacity | 270 | 2026-09-18 |
| Answered | AAbutPier | #268462 | Superstructure wind load in the calculation report | 191 | 2026-09-18 |
| Answered | AAbutPier | #268451 | Changing bearing location | 88 | 2026-09-18 |
| Answered | AAbutPier | #268445 | Main rebar placement | 292 | 2026-09-17 |
| Answered | AAbutPier | #268438 | Modeling error in seismic analysis | 407 | 2026-09-17 |
| Answered | AAbutPier | #268433 | Pier alignment center | 187 | 2026-09-17 |
| Answered | AAbutPier | #268431 | Please check the design ground surface displacement | 234 | 2026-09-17 |
| Answered | AAbutPier | #268422 | Question about pier | 265 | 2026-09-17 |
| Answered | AAbutPier | #268416 | Wprov calculation in the structural calculation report | 253 | 2026-09-17 |
| Answered | AAbutPier | #268402 | Increasing the number of column main rebars | 394 | 2026-09-16 |
| Answered | AAbutPier | #268392 | Question about cast-in-place piles | 225 | 2026-09-16 |
| Answered | AAbutPier | #268387 | Error when entering reinforcing rebar | 178 | 2026-09-16 |