About the shear check location for piers
이교각의 전단검토위치가 소성구간인 띠철근7.5cm구간에서 하고 있는데요. 전단철근 간격이 제일 큰곳에서 해야 되지 않을까요? 검토부탁합니다.
Answer
안녕하세요. 한길아이티입니다. 말씀하신 바와 같이 전단검토시의 배치간격은 소성구간이 아닌 기둥의 중앙부에서 간격을 취하도록 되어 있습니다. 해당 교각의 경우 높이가 짧은 경우 잘못된 간격을 찾는 경우가 있어 75mm로 출력이 되었습니다. 이 부분은 보완하여 패치에 적용하도록 하겠습니다. 보완사항에 대한 적용은 [개인정보]자 패치에 반영하겠습니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #268560 | Question about the calculation report | 181 | 2026-09-29 |
| Answered | AAbutPier | #268548 | Tendon force when placing tendons in the pier cap | 219 | 2026-09-29 |
| Answered | AAbutPier | #268520 | Pier seismic check | 251 | 2026-09-23 |
| Answered | AAbutPier | #268509 | Transverse reinforcement factor, K | 199 | 2026-09-22 |
| Answered | AAbutPier | #268492 | Girder positions in slab dimensions | 335 | 2026-09-21 |
| Answered | AAbutPier | #268483 | Transverse pile member forces are "0" in pier pile foundation check | 198 | 2026-09-21 |
| Answered | AAbutPier | #268482 | Top and bottom rebar detailing error in pier foundation STM | 221 | 2026-09-21 |
| Answered | AAbutPier | #268476 | Question about slab dimensions | 307 | 2026-09-19 |
| Answered | AAbutPier | #268470 | Settlement and bearing capacity | 270 | 2026-09-18 |
| Answered | AAbutPier | #268462 | Superstructure wind load in the calculation report | 191 | 2026-09-18 |
| Answered | AAbutPier | #268451 | Changing bearing location | 88 | 2026-09-18 |
| Answered | AAbutPier | #268445 | Main rebar placement | 292 | 2026-09-17 |
| Answered | AAbutPier | #268438 | Modeling error in seismic analysis | 407 | 2026-09-17 |
| Answered | AAbutPier | #268433 | Pier alignment center | 187 | 2026-09-17 |
| Answered | AAbutPier | #268431 | Please check the design ground surface displacement | 234 | 2026-09-17 |
| Answered | AAbutPier | #268422 | Question about pier | 265 | 2026-09-17 |
| Answered | AAbutPier | #268416 | Wprov calculation in the structural calculation report | 253 | 2026-09-17 |
| Answered | AAbutPier | #268402 | Increasing the number of column main rebars | 394 | 2026-09-16 |
| Answered | AAbutPier | #268392 | Question about cast-in-place piles | 225 | 2026-09-16 |
| Answered | AAbutPier | #268387 | Error when entering reinforcing rebar | 178 | 2026-09-16 |