AnsweredAAbutPierQ&A #1944522005-09-06 18:44 · Views 27

Pier step height looks wrong

교각 단차가 이상하게 적용 되었습니다. 단차가 겹쳐져 있습니다. 확인 부탁합니다.

Answer

안녕하세요. 한길아이티입니다. 교각1의 경우 종방향 변단면이 아니고 연결부 교각도 아닌 것같습니다. 교각 설계환경에서 종방향 변단면이 체크가 되어 있어 잘못된 자료가 들어가 있습니다. 연결부 교각을 체크하시고 종방향 변단면은 해제하신 후 다시 연결부 교각을 해제하시면 됩니다. 수정한 파일을 첨부하니 참조하시기 바랍니다. 감사합니다.

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1812026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2192026-09-29
AnsweredAAbutPier#268520Pier seismic check2512026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K1992026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check1992026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2212026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3082026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2702026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1912026-09-18
AnsweredAAbutPier#268451Changing bearing location882026-09-18
AnsweredAAbutPier#268445Main rebar placement2922026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4072026-09-17
AnsweredAAbutPier#268433Pier alignment center1872026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2342026-09-17
AnsweredAAbutPier#268422Question about pier2652026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2532026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3942026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2252026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1782026-09-16
Sign in to ask