Question about entering pier sections
첨부화일을 참조하시기 바라며 교각 측면 입력이 완벽하게 안되는군요. 방법을 알려주시기 바랍니다.
Follow-up2005-08-10 17:31
화일이 한번에 여러개는 안되네요.. pier 입력 화일입니다.
Answer2005-08-11 09:27
안녕하세요. 한길아이티입니다. 보내주신 도면은 AAbutPier에서 지원하지 않는 형식입니다. AAbutPier의 경우는 교대/교각의 개수가 많아 여러개의 교량을 한개의 파일에 모델링하는 기능은 제공하지 않습니다. 감사합니다.
Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #268560 | Question about the calculation report | 181 | 2026-09-29 |
| Answered | AAbutPier | #268548 | Tendon force when placing tendons in the pier cap | 219 | 2026-09-29 |
| Answered | AAbutPier | #268520 | Pier seismic check | 253 | 2026-09-23 |
| Answered | AAbutPier | #268509 | Transverse reinforcement factor, K | 202 | 2026-09-22 |
| Answered | AAbutPier | #268492 | Girder positions in slab dimensions | 335 | 2026-09-21 |
| Answered | AAbutPier | #268483 | Transverse pile member forces are "0" in pier pile foundation check | 202 | 2026-09-21 |
| Answered | AAbutPier | #268482 | Top and bottom rebar detailing error in pier foundation STM | 221 | 2026-09-21 |
| Answered | AAbutPier | #268476 | Question about slab dimensions | 309 | 2026-09-19 |
| Answered | AAbutPier | #268470 | Settlement and bearing capacity | 271 | 2026-09-18 |
| Answered | AAbutPier | #268462 | Superstructure wind load in the calculation report | 193 | 2026-09-18 |
| Answered | AAbutPier | #268451 | Changing bearing location | 88 | 2026-09-18 |
| Answered | AAbutPier | #268445 | Main rebar placement | 292 | 2026-09-17 |
| Answered | AAbutPier | #268438 | Modeling error in seismic analysis | 408 | 2026-09-17 |
| Answered | AAbutPier | #268433 | Pier alignment center | 188 | 2026-09-17 |
| Answered | AAbutPier | #268431 | Please check the design ground surface displacement | 235 | 2026-09-17 |
| Answered | AAbutPier | #268422 | Question about pier | 265 | 2026-09-17 |
| Answered | AAbutPier | #268416 | Wprov calculation in the structural calculation report | 253 | 2026-09-17 |
| Answered | AAbutPier | #268402 | Increasing the number of column main rebars | 396 | 2026-09-16 |
| Answered | AAbutPier | #268392 | Question about cast-in-place piles | 225 | 2026-09-16 |
| Answered | AAbutPier | #268387 | Error when entering reinforcing rebar | 179 | 2026-09-16 |