Skip to content
AnsweredAAbutPierQ&A #1938792005-08-10 13:25 · Views 46

Foundation bearing capacity check

교대 계산을 메스콘크리트를 고려하였는데 기초 지지력 검토시 메스콘크리트 자중이 고려 되었는지 확인하고 싶은데 계산서에 어느부분에 포함되어있는지 궁금해서.... 연락 주세요

Answer

안녕하세요. 한길아이티입니다. 교대입력>>설계환경>>설계선택사항에서 기초안정검토시 mass작용력 옵션에서 적용으로 선택하셔야 적용이 됩니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1812026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2192026-09-29
AnsweredAAbutPier#268520Pier seismic check2532026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K2022026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check2022026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2212026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3092026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2712026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1932026-09-18
AnsweredAAbutPier#268451Changing bearing location882026-09-18
AnsweredAAbutPier#268445Main rebar placement2922026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4082026-09-17
AnsweredAAbutPier#268433Pier alignment center1882026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2352026-09-17
AnsweredAAbutPier#268422Question about pier2652026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2532026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3962026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2252026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1792026-09-16
Sign in to ask