교각을 설계하려고 하는데 선형입력은 꼭 aline 이 있어야 하나요? 또 aline은 꼭 aroad를 깔아야 하나요? 원래 이렇다면 aroad가 없으면 안된다는 야그로 들리는데.. 끼워팔기 아닌가요? aline 없이 apier에서 선형입력하게 해주세요!
Answer
안녕하세요. 한길아이티입니다. 교각만을 설계하려면 선형없이도 설계가 가능하게 프로그램되어 있습니다. 선형입력을 하시면 내진설계가가 가능하고 각종 좌표와 EL값이 자동계산되므로 설계가 편리합니다. 선형프로그램인 Aline은 저희가 판매하는 모든제품에 포함되어 있습니다. AAbutpier가 깔려있는 폴더를 살펴보시기 바랍니다. 저희는 끼워팔기를 하지 않습니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #268560 | Question about the calculation report | 181 | 2026-09-29 |
| Answered | AAbutPier | #268548 | Tendon force when placing tendons in the pier cap | 219 | 2026-09-29 |
| Answered | AAbutPier | #268520 | Pier seismic check | 253 | 2026-09-23 |
| Answered | AAbutPier | #268509 | Transverse reinforcement factor, K | 202 | 2026-09-22 |
| Answered | AAbutPier | #268492 | Girder positions in slab dimensions | 335 | 2026-09-21 |
| Answered | AAbutPier | #268483 | Transverse pile member forces are "0" in pier pile foundation check | 202 | 2026-09-21 |
| Answered | AAbutPier | #268482 | Top and bottom rebar detailing error in pier foundation STM | 221 | 2026-09-21 |
| Answered | AAbutPier | #268476 | Question about slab dimensions | 309 | 2026-09-19 |
| Answered | AAbutPier | #268470 | Settlement and bearing capacity | 271 | 2026-09-18 |
| Answered | AAbutPier | #268462 | Superstructure wind load in the calculation report | 193 | 2026-09-18 |
| Answered | AAbutPier | #268451 | Changing bearing location | 88 | 2026-09-18 |
| Answered | AAbutPier | #268445 | Main rebar placement | 292 | 2026-09-17 |
| Answered | AAbutPier | #268438 | Modeling error in seismic analysis | 408 | 2026-09-17 |
| Answered | AAbutPier | #268433 | Pier alignment center | 188 | 2026-09-17 |
| Answered | AAbutPier | #268431 | Please check the design ground surface displacement | 235 | 2026-09-17 |
| Answered | AAbutPier | #268422 | Question about pier | 265 | 2026-09-17 |
| Answered | AAbutPier | #268416 | Wprov calculation in the structural calculation report | 253 | 2026-09-17 |
| Answered | AAbutPier | #268402 | Increasing the number of column main rebars | 396 | 2026-09-16 |
| Answered | AAbutPier | #268392 | Question about cast-in-place piles | 225 | 2026-09-16 |
| Answered | AAbutPier | #268387 | Error when entering reinforcing rebar | 179 | 2026-09-16 |