Skip to content
AnsweredAAbutPierQ&A #1933042005-07-14 18:11 · Views 41

Error during seismic analysis

안녕하세요..좋은 아침입니다... 교각 내진 해석 모델링에서 sap2000 자동실행을 하면 error가 발생합니다.. 바쁘시더라도 답변 좀 부탁드립니다.

Answer

안녕하세요. 한길아이티입니다. 가로보제원입력에서 설정한 가로보타입은 1번만 입력되었으나, 적용은 2번까지 되었기에 없는 단면을 프로그램에서 찾을수가 없어서 발생한 오류입니다. 새로 수정한 파일을 첨부하오니 참조하시기 바랍니다. 감사합니다. 안녕하세요. 한길아이티입니다. [내진해석 가로보 설정]에 보시면 가로보 단면은 1개로 설정이 되어있으나 2변단면이 지정된 곳이 있습니다. 단면을 2개로 늘려주시기거나 전체가로보에 단면을 "1"로 지정하신 후에 확인하시면 이상이 없습니다. 감사합니다.

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1812026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2202026-09-29
AnsweredAAbutPier#268520Pier seismic check2552026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K2022026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check2032026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2232026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3092026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2722026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1932026-09-18
AnsweredAAbutPier#268451Changing bearing location882026-09-18
AnsweredAAbutPier#268445Main rebar placement2922026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4082026-09-17
AnsweredAAbutPier#268433Pier alignment center1882026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2352026-09-17
AnsweredAAbutPier#268422Question about pier2672026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2542026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3962026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2252026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1802026-09-16
Sign in to ask