Skip to content
AnsweredAAbutPierQ&A #1931152005-07-07 19:16 · Views 35

Foundation layout error in span configuration input window

바쁘신거 아는데, 계속 이렇게 실례를 무릅쓰고 문의를 드리게 되네요. 교각기초 제원을 모두 입력했는데, 지간구성 입력창의 기초배치가 잘못 되어 있는 것 같아 문의 드리는 겁니다. 교랑받침의 센터가 교각기초의 센터에 오도록 교각기초의 제원을 입력했는데, 지간구성 입력창의 기초배치가 안바뀌네요. 파일 첨부하니 검토하여 주십시오.

Answer

안녕하세요. 한길아이티입니다. 기둥식 교각인 경우 TB값은 불필요한 값입니다. [교각입력]-[단면도제원]에서 TB값을 "0"으로 입력하신 후에 확인하시면 됩니다. 감사합니다.

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1812026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2202026-09-29
AnsweredAAbutPier#268520Pier seismic check2552026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K2022026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3352026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check2032026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2232026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3092026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2722026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1932026-09-18
AnsweredAAbutPier#268451Changing bearing location882026-09-18
AnsweredAAbutPier#268445Main rebar placement2922026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4102026-09-17
AnsweredAAbutPier#268433Pier alignment center1882026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2352026-09-17
AnsweredAAbutPier#268422Question about pier2672026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2542026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3982026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2252026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1802026-09-16
Sign in to ask