Skip to content
AnsweredAAbutPierQ&A #1918942005-05-18 18:48 · Views 39

Inquiry about changing rebar properties

교대벽체의 수직철근이 철근제원5(반경이있는 갈고리)로 되어있는데 이것을 철근제원2(반경0, 직각)로 바꾸려고 합니다. 배면 1단철근은 잘되는데 배면 2단, 전면 철근은 반경입력란을 삭제하면 철근이 출력되지않습니다. 그리고 글번호14498 겹이음길이 문의드렷었는데요. 묻고답하기 5533글에 필요하다면 겹이음 계산근거를 보내주신다고 하셨는데 첨부화일의 W1, W2철근의 겹이음길이 계산 근거를 보내주시면 감사하겠습니다.

Answer

안녕하세요. 한길아이티입니다. 벽체 수직철근의 상세를 직각으로 적용하시려면 [교대입력]-[벽체부배근]에서 "벽체수직철근 절곡부 처리" 에서 "직각"을 선택하시면 됩니다. 그리고 겹이음에 대한 부분은 계산하신 자료를 보내주시면 검토후 답변드리겠습니다. 감사합니다.

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1812026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2212026-09-29
AnsweredAAbutPier#268520Pier seismic check2572026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K2022026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3382026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check2032026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2242026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3122026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2742026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1932026-09-18
AnsweredAAbutPier#268451Changing bearing location882026-09-18
AnsweredAAbutPier#268445Main rebar placement2942026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4112026-09-17
AnsweredAAbutPier#268433Pier alignment center1892026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2362026-09-17
AnsweredAAbutPier#268422Question about pier2682026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2542026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3982026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2262026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1802026-09-16
Sign in to ask