Skip to content
AnsweredAAbutPierQ&A #1911702005-03-28 19:26 · Views 60

Error after coping beam reinforcement detailing

교각 두부보 배근후 다음을 클릭하면 내부 응용프로그램 오류가 뜨네요 단면도 제원에서보이는 교각7의 코핑쪽이 조금 이상하게 그려지네요

Answer

안녕하세요. 한길아이티입니다. 1) 교각 두부보 배근후 다음을 클릭하면 내부 응용프로그램 오류가 뜨네요 => 다음 메뉴 진행시의 오류는 확인하지 못하였습니다. 다시 한 번 확인해 주시기 바랍니다. 2) 단면도 제원에서보이는 교각7의 코핑쪽이 조금 이상하게 그려지네요 => 교각1,교각7은 종방향 변단면으로 설정되었으나 폭(W)에 대한 입력이 누락되어 있습니다. 값을 입력하신 후에 확인하여 주시기 바랍니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1812026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2212026-09-29
AnsweredAAbutPier#268520Pier seismic check2572026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K2022026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3462026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check2032026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2242026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3122026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2742026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1932026-09-18
AnsweredAAbutPier#268451Changing bearing location882026-09-18
AnsweredAAbutPier#268445Main rebar placement2972026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4112026-09-17
AnsweredAAbutPier#268433Pier alignment center1892026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2372026-09-17
AnsweredAAbutPier#268422Question about pier2692026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2562026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3982026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2262026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1802026-09-16
Sign in to ask