AnsweredAAbutPierQ&A #1911162005-03-23 19:06 · Views 142

Beam gap at continuous joint

PSC BEAM계산시 연속부(PIER)빔 유간을 100mm으로 조절이 가능한지 여부와 시종점부에서 빔과 슬래브 끝단거리최소거리를 도로중심선 방향이 50mm로 수정할수 없는지 답변부탁합니다.

Answer

안녕하세요. 한길아이티입니다. 1. 유간을 일정길이로 조정 가능합니다. . [일반입력>>지점각도입력>>거더 자동 배치>>거더정보 상세 입력]에서 를 "50"으로 입력. . 을 해제하신 다음 . 를 실행하면 됩니다. 2. 현재는 도로 중심선이 아닌 슬래브 끝단과의 직선거리로 적용됩니다. 도로중심선 거리를 원한다면 역으로 계산 또는 추정하셔서 설정하면 됩니다. 기타 의문 사항이 있으시면 연락 부탁드립니다. [한길 담당자] 사장 [전화] 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1812026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2212026-09-29
AnsweredAAbutPier#268520Pier seismic check2572026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K2022026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3462026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check2032026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2242026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3122026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2742026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1932026-09-18
AnsweredAAbutPier#268451Changing bearing location882026-09-18
AnsweredAAbutPier#268445Main rebar placement2972026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4112026-09-17
AnsweredAAbutPier#268433Pier alignment center1892026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2372026-09-17
AnsweredAAbutPier#268422Question about pier2692026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2562026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3982026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2262026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1802026-09-16
Sign in to ask