AnsweredAAbutPierQ&A #1904122005-01-28 18:33 · Views 68

Core confinement rebar

3경간연속 steelbox교량에서 T형교각설계중 의문이 생겨서요 기둥은 트랙형이고, fix단교각의 소성설계중 심부구속구간의 철근제원을 변경하여도 설계검토에서 cross tie의 개수가 변경되지 않아서 NG가 됩니다. 화일첨부하니 검토 부탁드립니다. (참고로 fck=240, fy=4000 입니다.)

Answer

안녕하세요. 한길아이티입니다. 트랙형 설계검토시 겹이음 구간의 크로스타이 개수가 적용되어 철근개수가 잘못 산정되었습니다. 수정하였으며 금일 오전에 패치에 적용하도록 하겠습니다. 패치는 자동업데이트로 하시면 됩니다. (업데이트시 최신버전경고는 무시하셔도 됩니다.) 감사합니다.

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1812026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2212026-09-29
AnsweredAAbutPier#268520Pier seismic check2572026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K2022026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3472026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check2032026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2242026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3122026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2742026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1932026-09-18
AnsweredAAbutPier#268451Changing bearing location882026-09-18
AnsweredAAbutPier#268445Main rebar placement2992026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4112026-09-17
AnsweredAAbutPier#268433Pier alignment center1892026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2372026-09-17
AnsweredAAbutPier#268422Question about pier2712026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2572026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3982026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2262026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1802026-09-16
Sign in to ask