Skip to content
AnsweredAAbutPierQ&A #1878512004-09-07 23:14 · Views 58

Program freezes while generating drawings

도면생성도중 프로그램이 멈추어버리네요 파일첨부합니다. 바쁘시겠지만 검토바랍니다

Answer

안녕하세요. 한길아이티입니다. 하행선 A1의 우측날개벽에 대한 철근입력이 누락되어 있습니다. 주철근, 전단 및 배력철근 모두 입력하여 주시고 확인해보시기 바랍니다. 철근제원도 설정이 되지않은 상태라 [철근제원]입력에서 A1 우측날개벽에 대하여 권고안을 해주시기 바랍니다. 권고안을 한 후 배면변단면부에서 기초를 벗어난 부분에 철근이 설정되지 않는 부분은 수정하여 패치에 적용하도록 하겠습니다. 감사합니다.

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#268560Question about the calculation report1812026-09-29
AnsweredAAbutPier#268548Tendon force when placing tendons in the pier cap2222026-09-29
AnsweredAAbutPier#268520Pier seismic check2572026-09-23
AnsweredAAbutPier#268509Transverse reinforcement factor, K2022026-09-22
AnsweredAAbutPier#268492Girder positions in slab dimensions3642026-09-21
AnsweredAAbutPier#268483Transverse pile member forces are "0" in pier pile foundation check2032026-09-21
AnsweredAAbutPier#268482Top and bottom rebar detailing error in pier foundation STM2242026-09-21
AnsweredAAbutPier#268476Question about slab dimensions3132026-09-19
AnsweredAAbutPier#268470Settlement and bearing capacity2742026-09-18
AnsweredAAbutPier#268462Superstructure wind load in the calculation report1942026-09-18
AnsweredAAbutPier#268451Changing bearing location902026-09-18
AnsweredAAbutPier#268445Main rebar placement3052026-09-17
AnsweredAAbutPier#268438Modeling error in seismic analysis4112026-09-17
AnsweredAAbutPier#268433Pier alignment center1892026-09-17
AnsweredAAbutPier#268431Please check the design ground surface displacement2372026-09-17
AnsweredAAbutPier#268422Question about pier2752026-09-17
AnsweredAAbutPier#268416Wprov calculation in the structural calculation report2622026-09-17
AnsweredAAbutPier#268402Increasing the number of column main rebars3982026-09-16
AnsweredAAbutPier#268392Question about cast-in-place piles2262026-09-16
AnsweredAAbutPier#268387Error when entering reinforcing rebar1802026-09-16
Sign in to ask