AnsweredAAbutPierQ&A #1379872016-04-21 10:48 · Views 321

Follow-up question on LSD pile calculation

1. 나) 말뚝 축압축과 휨의 조합 검토 에서 APIER 생성 계산서를 보면 'Pu/Pr ≥ 0.2 이면, Pu/Pr + (9/8)·(Mu/Mr) ≤ 1.00' 으로 표기되고 검토결과도 계산해보면 이 식을 적용하는데요. 도.설.한 6.9.2.2 식(6.9.3)은 'Pu/Pr ≥ 0.2 이면, Pu/Pr + (8/9)·(Mu/Mr) ≤ 1.00' 입니다. 확인부탁드립니다. 2. 다) 말뚝의 전단응력 검토 에서 Vr = Φv · Vn Vr = Φv · Vn > Vu = H (kN) 로 수정되야 할 것 같습니다. 계산서 테이블은 맞게 나오는것 같습니다.

Answer

안녕하세요. 한길아이티입니다. 1. 축압축과 휨의 조합에서 분수값의 표기 및 적용을 수정하였습니다. 2. 전단검토에서 공칭강도와 작용전단력의 조건식 표기를 수정하였습니다. 감사합니다.

More in this list

StatusProductNo.TitleViewsDate
AnsweredAAbutPier#207975Wing wall rebar (inner and outer)?292007-11-07
AnsweredAAbutPier#207974Cannot view or generate drawings402007-11-07
AnsweredAAbutPier#207970Tie bar placement in columns?412007-11-06
AnsweredAAbutPier#207959Design settings input error282007-11-06
AnsweredAAbutPier#207956Rebar detailing error242007-11-06
AnsweredAAbutPier#207954Parapet wall section error with wing wall on one side only222007-11-06
AnsweredAAbutPier#207951Rebar diameter looks wrong in cast-in-place pile drawing232007-11-06
AnsweredAAbutPier#207976Abutment earthwork quantity calculation312007-11-06
AnsweredAAbutPier#207971Question on strength reduction in column check442007-11-06
AnsweredAAbutPier#207969Minimum spacing error for confinement rebar752007-11-06
AnsweredAAbutPier#207966Incorrect foundation size in drawing612007-11-06
AnsweredAAbutPier#207962Bearing seat position error332007-11-06
AnsweredAAbutPier#207960Shoe angle at A1 fixed support looks wrong222007-11-06
AnsweredAAbutPier#207957Column recess reinforcement drawing error252007-11-06
AnsweredAAbutPier#207950Berm treatment for front embankment382007-11-06
AnsweredAAbutPier#207943Seismic analysis error342007-11-06
AnsweredAAbutPier#207931Please review foundation design382007-11-06
AnsweredAAbutPier#207939Drawing format error in Tools422007-11-05
AnsweredAAbutPier#207934Question172007-11-05
AnsweredAAbutPier#207932Can substructure use T-pier + T-pier?282007-11-05
Sign in to ask