u-type 구간 부력방지앵커를 설치하였는데 계산서 출력시 n,g로 뜹니다. 확인부탁드립니다.
Answer
안녕하세요. 한길아이티입니다. 부력검토의 안정검토시 N.G 가 나오는건 전체 부력검토시 안전율을 만족하지 못하기 때문에 N.G 가 나오는 것이며 부력방지 앵커의 설계력을 제시하여 설계력보다 큰 값의 앵커력을 입력하도록 유도한다고 보시면 됩니다. 앵커 설계력에 만족하는 앵커력을 입력하셔도 안정검토시에서 보여주는 N.G 는 부력에 대한 안전율에 대한 판단이기 때문에 앵커력 입력과는 무관한 부분 입니다. 감사합니다.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | ACulvert | #226145 | Culvert general drawing | 69 | 2005-05-23 |
| Answered | ACulvert | #226143 | Typical section drawing | 54 | 2005-05-20 |
| Answered | ACulvert | #226141 | Please check an Excel output error | 57 | 2005-05-20 |
| Answered | ACulvert | #226139 | Check for missing support conditions | 56 | 2005-05-20 |
| Answered | ACulvert | #226137 | Missing support conditions | 59 | 2005-05-20 |
| Answered | ACulvert | #226134 | Changing approach slab rebar diameter | 68 | 2005-05-19 |
| Answered | ACulvert | #226133 | Inquiry about retaining wall-type wing walls | 61 | 2005-05-19 |
| Answered | ACulvert | #226131 | Calculation of a culvert with separate roadway and sidewalk | 64 | 2005-05-17 |
| Answered | ACulvert | #226129 | Inquiry about bearing capacity check | 76 | 2005-05-16 |
| Answered | ACulvert | #226126 | Please check earth pressure | 90 | 2005-05-12 |
| Answered | ACulvert | #226125 | Question about SAP input data | 70 | 2005-05-12 |
| Answered | ACulvert | #226123 | Calculation report output error | 72 | 2005-05-11 |
| Answered | ACulvert | #226121 | Inquiry about live load error | 76 | 2005-05-11 |
| Answered | ACulvert | #226119 | Question about output | 66 | 2005-05-10 |
| Answered | ACulvert | #226117 | Section check for the negative moment region | 95 | 2005-05-09 |
| Answered | ACulvert | #226113 | Inquiry about retaining wall wing wall calculation report | 58 | 2005-05-07 |
| Answered | ACulvert | #226111 | Please check (shear reinforcement question) | 57 | 2005-05-06 |
| Answered | ACulvert | #226115 | Coefficient of subgrade reaction | 111 | 2005-05-06 |
| Answered | ACulvert | #226109 | Please check | 53 | 2005-05-04 |
| Answered | ACulvert | #226107 | Concrete strength for cutoff wall lean concrete | 86 | 2005-05-03 |