Skip to content
AnsweredACulvertQ&A #1359482015-12-03 03:29 · Views 216

Inquiry about section check

개거 단면검토시 같은 조건인데~~ 좌측벽체중앙부와 우측벽체중앙부가 모멘트가 왜 다른지 궁금합니다~

Answer

안녕하세요. 한길아이티입니다. 문의하신 부분 수정후 패치 되었습니다. Aupdate 통하여 최신버전 update 후 사용하시기 바랍니다. 감사합니다.