AnsweredACulvertQ&A #1340012015-07-28 10:48 · Views 655

Corner and inner tension rebar error

첨부파일에 보시면 4종류의 암거를 설계중입니다. 4종류 모든 암거 다 검토 부탁드립니다. 1. 내측인장 철근을 배근했음에도 불구하고 사용철근량이 0으로 나오면서 NG 2. Skew가 고려가 안된 단면임에도 불구하고 우각부 1단 위치가 좌우가 다르게 나옵니다.(R1,R2가 배치가 다르게 표현됨)

Answer

안녕하세요. 한길아이티입니다. 1. 2D frame 해석후 다음다음 클릭하여 철근 제원까지 가서 전체 기본값 클릭후 스터럽 철근에 대한 내측인장에 대한 검토를 다시 확인 하여 보시기 바랍니다. 2. 수정후 패치 하여 드리겠습니다. 감사합니다.

Answer

안녕하세요. 한길아이티입니다. 2. 단절점부 철근의 배치에 오류가 확인되어 수정하였습니다. 패치후 정상적으로 적용됩니다. 감사합니다.

Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.

More in this list

StatusProductNo.TitleViewsDate
AnsweredACulvert#196120Ground reaction (BxL)442005-11-17
AnsweredACulvert#196047Main rebar design check112005-11-15
AnsweredACulvert#195723Correction request202005-10-31
AnsweredACulvert#195545Standard cross-section drawing122005-10-24
AnsweredACulvert#195382Abnormal lap splice length and quantity calculation not working332005-10-17
AnsweredACulvert#193933Question about wing walls232005-08-12
AnsweredACulvert#193937Plan view52005-08-12
AnsweredACulvert#193360File172005-07-16
AnsweredACulvert#192582Pedestrian culvert program error232005-06-14
AnsweredACulvert#192418Inquiry about wing walls312005-06-08
AnsweredACulvert#191641Please review392005-04-23
AnsweredACulvert#191511Shouldn't the corner reinforcing rebar detail be changed?342005-04-15
AnsweredACulvert#191504Buoyancy check looks wrong262005-04-15
AnsweredACulvert#189303Data attached, please check142004-11-25
AnsweredACulvert#189017ACulvert trial version342004-11-09
AnsweredACulvert#188979Please check error in seismic case282004-11-06
AnsweredACulvert#188574Main rebar input and design check182004-10-19
AnsweredACulvert#187045Error when printing structural calculation report112004-07-19
AnsweredACulvert#185899sap2000 stops with an error while running232004-05-25
AnsweredACulvert#185377Program does not run682004-04-01
Sign in to ask