Errors in column shear check and confinement rebar calculation
내용은 한글 첨부파일에 기재하였음. 빠른 답변 부탁드립니다.
Answer
안녕하세요. 한길아이티입니다. 도로교 설계기준 2010 이상에서는 기둥 및 기초의 전단철근의 강도를 별도 설정할 수 있도록 되어있습니다. 해당 강도를 확인 부탁드립니다. 심부구속철근은 심부구간에 적용된 철근이 반영됩니다. 현재 심부구간으로 적용된 구간이 없어 해당 검토에서 적용되는 철근량이 없는 것으로 심부구간 설정 및 직경을 설정하시면 반영될 것입니다. 감사합니다.
Attachments on this post were deleted after the retention period (3 years after the last answer) and can no longer be downloaded. If you need the same material, please contact us.
More in this list
| Status | Product | No. | Title | Views | Date |
|---|---|---|---|---|---|
| Answered | AAbutPier | #198896 | PSC beam girder slope | 50 | 2006-06-06 |
| Answered | AAbutPier | #198893 | Please check bearing seat rebar | 55 | 2006-06-06 |
| Answered | AAbutPier | #198891 | How to enter EL | 63 | 2006-06-06 |
| Answered | AAbutPier | #198885 | Seismic analysis modeling | 57 | 2006-06-05 |
| Answered | AAbutPier | #198887 | Importing alignment | 43 | 2006-06-05 |
| Answered | AAbutPier | #198883 | Bearing dimensions look wrong in pier general drawing output | 79 | 2006-06-03 |
| Answered | AAbutPier | #198882 | Error in pile reaction calculation | 58 | 2006-06-03 |
| Answered | AAbutPier | #198878 | Rebar numbering in abutment reinforcement drawing | 40 | 2006-06-02 |
| Answered | AAbutPier | #198875 | MPL calculation | 69 | 2006-06-02 |
| Answered | AAbutPier | #198873 | Widened bridge | 74 | 2006-06-02 |
| Answered | AAbutPier | #198872 | Two-layer reinforcement in foundation | 63 | 2006-06-02 |
| Answered | AAbutPier | #198866 | Foundation shear force output reference error | 60 | 2006-06-01 |
| Answered | AAbutPier | #198863 | Spring stiffness | 61 | 2006-06-01 |
| Answered | AAbutPier | #198865 | Bearing number when entering superstructure loads | 41 | 2006-06-01 |
| Answered | AAbutPier | #198862 | Error occurs when generating drawings | 71 | 2006-06-01 |
| Answered | AAbutPier | #198858 | Pier check does not work | 47 | 2006-05-31 |
| Answered | AAbutPier | #198855 | Internal application error | 49 | 2006-05-30 |
| Answered | AAbutPier | #198857 | During drawing generation | 82 | 2006-05-30 |
| Answered | AAbutPier | #198851 | PC beam layout | 53 | 2006-05-30 |
| Answered | AAbutPier | #198847 | Is two-layer reinforcement not possible for wing walls? | 80 | 2006-05-29 |